Code CR3600DPM Technické informace Strana 44

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 72
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 43
10/29/2014
Page 44 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default
(Hex)
Comment
E5
Trigger 3 Confirmation
Time (ms)
0
Valid Range: 0 to 7FFFFFFF Milliseconds
The trigger input must be asserted for this amount of time before
the trigger event is generated. Setting this value > 0 makes it easier
to select combinations of triggers (e.g. trigger 3, which is trigger 1 &
2 asserted together).
E6
Trigger 4 Confirmation
Time (ms)
0
Valid Range: 0 to 7FFFFFFF Milliseconds
The trigger input must be asserted for this amount of time before
the trigger event is generated. Setting this value > 0 makes it easier
to select combinations of triggers (e.g. trigger 3, which is trigger 1 &
2 asserted together).
E7
Trigger 5 Confirmation
Time (ms)
0
Valid Range: 0 to 7FFFFFFF Milliseconds
The trigger input must be asserted for this amount of time before
the trigger event is generated. Setting this value > 0 makes it easier
to select combinations of triggers (e.g. trigger 3, which is trigger 1 &
2 asserted together).
E8
Trigger 6 Confirmation
Time (ms)
0
Valid Range: 0 to 7FFFFFFF Milliseconds
The trigger input must be asserted for this amount of time before
the trigger event is generated. Setting this value > 0 makes it easier
to select combinations of triggers (e.g. trigger 3, which is trigger 1 &
2 asserted together).
E9
Trigger 7 Confirmation
Time (ms)
0
Valid Range: 0 to 7FFFFFFF Milliseconds
The trigger input must be asserted for this amount of time before
the trigger event is generated. Setting this value > 0 makes it easier
to select combinations of triggers (e.g. trigger 3, which is trigger 1 &
2 asserted together).
EB
Maximum Reader To
Host Packet Data Size
(bytes)
4000
(#16384)
Valid Range: 1 to 4000 (#16384) Bytes
EC
Host Acknowledgement
Time Limit Multiplier
(ms)
F
(#15)
Valid Range: 0 to 7FFFFFFF Milliseconds
When Expect Acknowledgement From Host (register 42) is nonzero,
the Reader will wait up to Host Acknowledgement Time Limit
(register 37) + dataSize * Host Acknowledgement Time Limit
Multiplier (register EC) milliseconds to receive an
acknowledgement from the Host.
ED
Prefix Decode Result
With AIM Symbology
Identifiers
0
0: Don’t prefix with AIM identifier
1: Prefix decode result with ISO/IEC standard 15424/AIM
symbology identifier
Zobrazit stránku 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 71 72

Komentáře k této Příručce

Žádné komentáře